Integrated 9/11/18/20 Cores 0.75mmsq UIC Databus Cables
FRL-UIC-4G10+2G6+1G2.5+2G0.75
FRL-UIC-4G10+2G6+1G2.5+2G1+2G0.75
FRL-UIC-4Q1S+2G0.75/FRL-UIC-4Q1S+2P0.75S

Application :

  • The cables are used as connecting cables to transmit digital signals inside railway rolling stocks.

Construction :

  • For 9 cores UIC databus cables :
  • 4 cores 10 mm2 stranded tinned copper conductor with LSZH insulation.
    Combined Element 3 cores (with Cu-strand 2 x 6mm2, 1 x 2.5mm2) are twisted with a filling element to a combined element.
      Core Wrapping Overlapped plastic-foil(s)
      Elements sheaths TPE
    UIC Data Bus 0.75mm2 Two foam PE or foam skin insulated tinned copper stranded conductors are twisted together with two filling elements to a pair.
      Core Wrapping Overlapped plastic-foil(s)
      Screen Tin plated copper braid
      Elements sheaths TPE
    Stranding 4 strands are twisted to a core together with 3 cored element, the UIC data bus and two fillers
    Core Wrapping Overlapped plastic-foil(s)
    Outer Sheath Cross-linked oil resistant LSZH compound
  •  

  • For 11 cores UIC databus cables :
  • 4 cores 10 mm2 stranded tinned copper conductor with LSZH insulation
    Combined Element 5 cores (with Cu-strand 2 x 6mm2, 1 x 2.5mm2 and 2 x 1.0 mm2) are twisted with a filling element to form a combined element.
      Core Wrapping Overlapped plastic-foil(s)
      Elements sheaths TPE
    UIC Data Bus 0.75mm2 Two foam PE or foam skin insulated tinned copper r stranded conductors are twisted together with two filling elements to a pair
      Core Wrapping Overlapped plastic-foil(s)
      Screen Tin plated copper braid
      Elements sheaths TPE
    Stranding 4 strands are twisted to a core together with 5 cored element, the UIC data bus and two fillers
    Core Wrapping Overlapped plastic-foil(s)
    Outer Sheath Cross-linked oil resistant LSZH compound
  •  

  • For 18/20 cores UIC databus cables :
  • Star Quad Four LSZH insulated 1mm2 stranded tinned copper conductors are twisted to form a star quad
    UIC Data Bus 0.75mm2 Two foam PE or foam skin insulated tinned copper stranded conductors are twisted together with two filling elements to form a pair
      Core Wrapping Overlapped plastic-foil(s)
      Screen Tin plated copper braid
      Elements sheaths TPE
    Stranding 4 star quads are stranded together with 2 or 4 UIC data bus cable and several fillers
    Core Wrapping Overlapped plastic-foil(s)
    Screen Tin plated copper braid
    Outer Sheath Cross-linked oil resistant LSZH compound

Electrical & Mechanical Properties :

  • Nominal Voltage 300V
    Maximum Temperature 90°C
    Minimum Temperature -40°C
    Bending Radius 12 x Overall Diameter

Chemical & Environmental Properties :

  • EN 60684-2 No fluorine
    EN 50305; EN 60811-2-1 Resistance to mineral oil & fuel oil, acid & alkali
    EN 50305 Resistance to ozone

Fire Performance for rolling stock application :

  • EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
    DIN 5510-2 Protection level 1/2/3/4
    BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
    NF F 16-101 F0

Fire Performance for rolling stock application :

  • EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propogation for a single insulated wire or cable
    EN 50266-2-4 + EN 50305; IEC 60332-3-24;
    NF C 32-070 2.2 (C1); VDE 0472 Teil 804
    Vertical flame spread of vertically mounted bunched wires or cables
    EN 50268-2; IEC 61034-2; NF C 32-073 ;
    NF C 20-902; NF F 16 101; VDE 0472 Teil 816
    Low Smoke Emission
    EN 50267-2-1; IEC 60754-1; NF C 32-074;
    NF C 20-454; VDE 0472 Teil 815
    Halogen Free

    EN 50267-2-2/3; IEC 60754-2; NF C 32-074;

    NF C 20-453; VDE 0472 Teil 813

    Low Corrosivity (Acidity & Conductivity)
    EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853
    Low Toxicity
    NF F 63 808; BS6853; NF F 16 101 Smoke index

FRL-UIC-4G10+2G6+1G2.5+2G0.75 :

  • Nominal Cross Sectional Area Number &
    Nominal
    Diameter
    of Strands
    Nominal
    Sheath
    Thickness
    Nominal
    Overall
    Diameter
    Nominal
    Weight
    Maximum
    Conductor
    Resistance
    Impedance Maximum Attenuation
    20°C @0.75-3MHz @1MHz @1.5MHz @2MHz @3MHz
    mm2 No/mm mm mm kg/km Ω/km Ω dB/km dB/km dB/km dB/km
    0.75 19/0.22 1.8 25 917 26.7 120+/-12 10 13 14 18
    10 80/0.4 1.95 - - - - -
    6 84/0.3 3.39 - - - - -
    2.5 37/0.29 8.21 - - - - -

FRL-UIC-4G10+2G6+1G2.5+2G1+2G0.75 :

  • Nominal Cross Sectional Area Number &
    Nominal
    Diameter
    of Strands
    Nominal
    Sheath
    Thickness
    Nominal
    Overall
    Diameter
    Nominal
    Weight
    Maximum
    Conductor
    Resistance
    Impedance Maximum Attenuation
    20°C @0.75-3MHz @1MHz @1.5MHz @2MHz @3MHz
    mm2 No/mm mm mm kg/km Ω/km Ω dB/km dB/km dB/km dB/km
    0.75 19/0.22 1.8 25 969 26.7 120+/-12 10 13 14 18
    10 80/0.4 1.95 - - - - -
    6 84/0.3 3.39 - - - - -
    2.5 37/0.29 8.21 - - - - -

FRL-UIC-4Q1S+2G0.75 :

  • Nominal Cross Sectional Area Number &
    Nominal
    Diameter
    of Strands
    Nominal
    Sheath
    Thickness
    Nominal
    Overall
    Diameter
    Nominal
    Weight
    Maximum
    Conductor
    Resistance
    Impedance Maximum Attenuation
    20°C @0.75-3MHz @1MHz @1.5MHz @2MHz @3MHz
    mm2 No/mm mm mm kg/km Ω/km Ω dB/km dB/km dB/km dB/km
    0.75 19/0.22 1.8 18.5 498 26.7 120+/-12 10 13 14 18
    1 19/0.25 20 - - - - -

FRL-UIC-4Q1S+2P0.75S :

  • Nominal Cross Sectional Area Number &
    Nominal
    Diameter
    of Strands
    Nominal
    Sheath
    Thickness
    Nominal
    Overall
    Diameter
    Nominal
    Weight
    Maximum
    Conductor
    Resistance
    Impedance Maximum Attenuation
    20°C @0.75-3MHz @1MHz @1.5MHz @2MHz @3MHz
    mm2 No/mm mm mm kg/km Ω/km Ω dB/km dB/km dB/km dB/km
    0.75 19/0.22 1.5 23 530 26.7 120+/-12 10 13 14 18
    1 19/0.25 20 - - - - -

 

Corona Resistant
Highly Flexible
UV Resistant
Ozone Resistant
Abrasion Retardant
Cold- resistant

 

Resistance To
Soldering Heat
Acid&Alkaline
Resistant
IRM 903
Fuel Oil Resistant
IRM 902
Mineral Oil Resistant
Fire Retardant
NF C32-070-2.2(C2)
IEC60332-3-24/EN50266-2-4
Flame Retardant
NF C32-070-2.1(C1)
IEC60332-1-2/EN50265-2-1

 

Low Toxicity
NF X70-100/NF F63 808
TM1-04/BS 6853
Low Corrosivity
IEC60754-2/EN50267-2-2/3
NF C32-074/VDE 0472-813
Low Smoke Emission
IEC 61034-2 / EN 50268-2
NF C32-073/VDE 0472-816
Zero Halogen
IEC 60754-1/EN 50267-2-1
NF C32-074//VDE 0472-815